Furnace and boiler recalls

46 safety recall notices since 2005, 13 of them in the last five years. The most recent is from 2026. The hazard cited most often is carbon monoxide (29 of 46).

Is yours on the list?

A recall names specific models and often a range of serial numbers. Take a photo of the label and we check the model against every notice below.

Take a photo of the labelType the model number instead

What the notices warn about

HazardNotices (of 46)
Carbon monoxide29
Fire16
Burns13
Gas leak or explosion5
Injury5
Electric shock2

A notice can cite more than one hazard.

All notices, newest first

NTI and HTP Brand Gas Boilers Recalled Due to Risk of Serious Injury or Death from Fire, Carbon Monoxide (CO) Poisoning and Impact Hazards; Manufactured by Ariston, formerly NTI Boilers2026-10-29 · 4,726 units

The condensate dish inside the boiler can crack during a delayed ignition, allowing unburned gas to build up inside the sealed cabinet. If the gas ignites, the front cover can suddenly detach, posing a risk of serious injury or death from fire, carbon monoxide (CO) poisoning, and impact hazards.

Combi Boilers Recalled Due to Burn Hazard; Manufactured by IBC Technologies2025-08-21 · About 1,100 units

A combi (or combination) boiler is a type of gas boiler that provides both a home's hot water and central heating. The hot water can exceed the temperature set on the control panel, posing a burn hazard to users.

HTP Brand Boilers Recalled Due to Fire and Carbon Monoxide (CO) Poisoning Hazards and Risk of Serious Injury or Death; Made by NTI Boilers2025-06-05 · About 96 units

The boiler door can fail to seal properly, due to incorrect burner door studs, allowing flames and gases to escape, posing fire and carbon monoxide (CO) poisoning hazards that can result in death or serious injury.

Rinnai America Recalls Boilers Due to Carbon Monoxide (CO) Poisoning Hazard2025-06-05 · About 2,030 units

The boiler door can fail to seal properly due to incorrect screws, allowing carbon monoxide (CO) gases to escape, posing a carbon monoxide poisoning hazard.

Triangle Tube Recalls Prestige and Aerco Esteem Gas Boilers Due to Carbon Monoxide (CO) Poisoning Hazard; Two Deaths Reported2025-02-27 · Approximately 60,000 units

The boilers can release carbon monoxide (CO) due to delayed ignitions or component damage, posing a risk of serious injury or death.

Crown Boiler Recalls Home Heating Boilers Due to Carbon Monoxide Poisoning Hazard2024-03-21 · About 1,100 units

The blocked vent switch (BVS) can fail to shut down the burners if the boilers are installed at altitudes above 2,000 feet and the vent system becomes blocked. In such an event, the boiler can emit excessive amounts of carbon monoxide into the building, posing a carbon monoxide (CO) poisoning hazard to consumers.

U.S. Boiler Company Recalls Gas-Fired Hot Water Residential Boilers Due to Carbon Monoxide Poisoning Hazard2024-03-14 · About 2,500 units

The blocked vent switch (BVS) can fail to shut down the burners if the boilers are installed at altitudes above 5,400 feet and the vent system becomes blocked. In such an event, the boiler can emit excessive amounts of carbon monoxide into the home, posing a carbon monoxide (CO) poisoning hazard to consumers.

Lochinvar Recalls Condensing Boilers Due to Risk of Carbon Monoxide Poisoning2023-11-02 · About 17, 370 units

The boiler's flue collector can crack if exposed to a high impact event in the burner chamber, which can allow the boiler to emit carbon monoxide, posing a risk of carbon monoxide poisoning.

ECR International Recalls Gas-Fired Hot Water Residential Boilers Due to Carbon Monoxide Poisoning Hazard2023-07-13 · About 1,745 units

The recalled residential boilers can be missing the flue inspection cover plate, posing a risk of exposure to combustion flue gasses and a carbon monoxide poisoning hazard.

Allied Air Enterprises Recalls Armstrong Air and Air Ease Gas Furnaces Due to Carbon Monoxide Poisoning Hazard2023-06-08 · About 9,255 units

A component inside the furnace was improperly assembled, causing the furnace to produce high levels of carbon monoxide (CO) under certain operating conditions, which poses a risk of CO poisoning to the consumer.

Burnham Commercial Recalls Natural Gas Boilers Due to Burn Hazard (Recall Alert)2023-03-23 · About 185 units

Delayed ignition and/or flame rollout can occur with the boilers, posing a burn hazard.

Laars Heating Systems Company Recalls Residential Boilers Due to Carbon Monoxide Hazard2022-06-30 · About 545 units

The blocked vent temperature switch (BVTS) can malfunction, which can cause the release of gases, including carbon monoxide (CO), into consumers' homes, posing a risk of carbon monoxide poisoning.

Triangle Tube Recalls to Repair Gas Boilers Due to Risk of Carbon Monoxide Hazard; One Death Reported; In-Home Remedy May Be Delayed Due To COVID-19 Restrictions2020-07-28 · About 63,000 units

Flue gas can escape from the gas boilers if the vent adapter is not securely reattached to the boiler after maintenance or repair, posing a carbon monoxide poisoning hazard to consumers.

Lochinvar Recalls Condensing Residential Boilers Due to Risk of Carbon Monoxide Poisoning2020-06-18 · About 34,300 units

The boiler's flue grommet can deteriorate and dislodge during use and allow the boiler to emit carbon monoxide, posing a risk of carbon monoxide poisoning.

Bosch Thermotechnology Recalls Buderus Boilers Due to Carbon Monoxide Poisoning Hazard2019-12-20 · About 170 units

The siphon can become blocked, leading to a delayed ignition that can damage the boiler's exhaust system, creating a carbon monoxide hazard.

Viessmann Recalls Boilers Due to Carbon Monoxide Hazard2019-04-25 · About 2,900 units

The boiler heat exchanger back plate can corrode and leak flue gases, allowing the boiler to emit excessive amounts of carbon monoxide, posing a CO poisoning hazard to consumers.

Hydrolevel Recalls Controllers for Slant/Fin Boilers Due to Fire Hazard2018-10-18 · About 3,900 units

A malfunction in the recalled controller can cause the boiler to overheat, posing a fire hazard.

NY Thermal Recalls Boilers Due to Carbon Monoxide Hazard2018-05-15 · About 16,000 units

The grommet seal can reduce in size over time and dislodge during use and allow the boiler to emit carbon monoxide, posing a CO poisoning hazard.

Goodman Recalls Furnaces Due to Electrical Shock Hazard2017-05-02 · About 4,100 units

The blower motor is not grounded, posing an electrical shock hazard to individuals servicing the units

Trane Recalls Furnaces Due to Shock Hazard (Recall Alert)2016-11-08 · About 17,700 units

The ground wire in the furnace's junction box can become loose. If an electrical component then fails and short circuits, the unit poses a shock hazard.

Carlin Recalls Williamson and Thermoflo Furnaces and Boilers Equipped with Carlin Burners Due to Fire Hazard (Recall Alert)2016-03-10 · About 110 units

A wiring malfunction can result in the burners failing to shut off, posing a fire hazard.

Viessmann Recalls Gas Boilers Due to Fire and Carbon Monoxide Hazard (Recall Alert)2016-02-25 · About 165 in the United States units

The boiler can overheat and emit flue gases into the venting system and carbon monoxide can leak throughout the residence, posing a fire and carbon monoxide hazard to consumers.

Fluid Handling Recalls Low Water Cut-Off Control Units for Hot Water or Steam Boilers Due to Fire and Explosion Hazards (Recall Alert)2014-10-09 · About 1,200 units

The ground wire and probe wires could be incorrectly assembled in the units by the manufacturer, posing fire and explosion hazards.

Weil-McLain Recalls Ultra Series Boilers Due to Risk of Fire, Explosion2014-06-10 · About 7,900 in the United States and 540 in Canada units

A cap on the boiler's manifold can crack and release gas into the home, posing a risk of fire and explosion.

New Yorker Boiler Recalls Home Heating Boilers Due to Carbon Monoxide Hazard2014-01-09 · About 191 units

The air pressure switch can fail to shut down the burners when there is a blockage in the vent system, allowing the boiler to emit excessive amounts of carbon monoxide and posing a CO poisoning hazard to the consumer.

U.S. Boiler Recalls Home Heating Boilers Due to Carbon Monoxide Hazard2014-01-09 · About 26,000 in the United States and about 310 in Canada units

The air pressure switch can fail to shut down the burners when there is a blockage in the vent system, allowing the boiler to emit excessive amounts of carbon monoxide and posing a CO poisoning hazard to the consumer.

Crown Boiler Recalls Home Heating Boilers Due to Carbon Monoxide Hazard2013-12-03 · About 2,200 units

The air pressure switch can fail to shut down the burners in the event that there is a blockage in the vent system allowing the boiler to emit excessive amounts of carbon monoxide, posing a CO poisoning hazard to the consumer.

Fire Concerns Prompt York International to Reannounce Recall of Gas Furnaces for Manufactured Homes2012-02-03 · About 223,600 in the U.S. and 2,400 in Canada units

The furnace can overheat and cause the heat-exchanger to crack and create openings that allow flames to be exposed. When this happens, drywall and other nearby combustibles are exposed to the flames, posing a fire and smoke hazard to consumers.

Bosch Thermotechnology Recalls Boiler Survey Kits Due to Fire Hazard2010-08-09 · About 1,500 units

The use of a silver-colored gas pipe adapter included in the service kit can lead to gas leakage, posing a fire or explosion hazard to consumers.

Gas Boilers Recalled by Bosch Thermotechnology Corp. Due to Carbon Monoxide Poisoning Hazard2009-09-23 · 85 units

A problem with the boiler's ignition due to insufficient output voltage from the boiler's transformer can damage the boiler's venting. This can result in leaking flue gases, posing a risk of carbon monoxide poisoning to consumers.

Furnaces Recalled by Northwest Manufacturing Due to Fire Hazard2009-09-17 · About 600 units

The temperature gauge can fail and cause fire in the fuel storage hopper, posing a fire and burn hazard to consumers.

Bosch Thermotechnology Recalls Boilers Due to Fire Hazard2009-07-09 · About 90 units

An electrical connector can overheat, posing a fire hazard to consumers.

Rheem Recalls to Repair Oil-Fired Furnaces Due to Fire Hazard2009-01-22 · About 14,000 units

If the furnace is not properly wired, the oil burner can continue to operate when the blower shuts off, posing a fire hazard to consumers.

Viessmann U.S. Recalls Boilers Due to Fire Hazard2008-10-02 · About 4,600 units

The boiler can leak gas, posing a fire hazard to consumers.

PB Heat Recalls Gas Boilers Due to Carbon Monoxide Hazard2008-09-11 · About 1,200 units

The pressure switch could have an internal defect that could fail to shut down the boilers under vent or air inlet blockage. This switch defect could allow the boilers to produce excessive levels of carbon monoxide, posing a risk of carbon monoxide poisoning to consumers.

Weil-McLain Gas Boilers Recalled Due to Carbon Monoxide Hazard2008-05-06 · About 32,000 units

If there is a leak in the vent piping, the recalled boilers can leak carbon monoxide (CO) into the buildings in which they are installed, posing a risk of CO poisoning.

Williamson-Thermoflo Gas Boilers Recalled Due to Carbon Monoxide Hazard2008-05-06 · About 1,800 units

If there is a leak in the vent piping, the recalled boilers can leak carbon monoxide (CO) into the buildings in which they are installed, posing a risk of CO poisoning.

Greenheck Fan Recalls Indirect Gas Fired Furnaces Due to Risk of Fire2008-02-21 · About 1,500 units

The ignition control module can fail preventing the unit from shutting down in high temperature conditions. This poses a risk of fire, as well as hazardous fumes being released from burning/melting insulation.

Rinnai Recalls Wall Furnaces Due to Carbon Monoxide Hazard2008-02-21 · About 52,000 units

A gasket in the unit can fail, posing a risk of poisonous carbon monoxide gas leaking into the home.

NY Thermal Inc. Recalls to Repair Gas-Fired Hot Water Boilers Due to Carbon Monoxide Hazard2007-04-05 · About 4,800 units

Acidic liquid in a drain line can cause a fitting in the boiler to leak, posing a risk of carbon monoxide (CO) poisoning to consumers.

TAC LLC Recalls "Erie Boiler Boss" Boiler Controls for Scald Hazard2007-01-25 · About 850 units

These boiler controls can fail, causing water temperature to rise to the high temperature limit. Should the high temperature thermostat or external safety limit devices also fail, consumers could suffer scalds from unexpectedly hot water during use or system piping damage can result.

Weil-McLain Co. Recalls Boilers for Leaking Exhaust, Carbon Monoxide2007-01-22 · 171 units

The boiler assembly is not properly sealed. Exhaust and carbon monoxide (CO) can leak during operation and accumulate, posing a risk of poisoning.

Crown Boiler Co. Recalls Boilers Due to Carbon Monoxide Poisoning Hazard2006-12-19 · About 400 units

The boilers can generate excessive levels of carbon monoxide (CO) in the flue gases, posing a risk of CO poisoning.

Weil-McLain Recalls Ultra Series Boilers for Carbon Monoxide Hazard2006-10-31 · About 16,000 units

These boilers were manufactured for use with natural gas, but could have a blue tag incorrectly indicating to installers that they are intended for use with LP (propane) gas. If an installer connects one of the boilers to LP gas without installing a propane conversion kit, carbon monoxide (CO) can build up due to incomplete combustion, posing a risk of CO poisoning.

CPSC, Weil-McLain Company Announce Recall of Boilers2006-02-01 · 1,131 units

The blower assembly is not properly sealed. Gas can leak during operation and accumulate. If an ignition source is present, a fire or explosion could occur.