Maytag dryer not heating

A dryer that tumbles but stays cold usually has a blocked vent, a half-tripped breaker on an electric model, or no gas reaching a gas model. Check the breaker, the lint screen and the vent outside first. If those are fine, a part inside has failed, most often the thermal fuse or the heating element, and that is a technician's job.

First: If you smell gas, stop. Leave the house and call your gas company or 911 from outside.

Take a photo of the label

We'll work out which of these fits your exact model, and whether it is safe to fix yourself.

What a Maytag shows for this

If the display shows a code, it narrows the cause down. Maytag uses these 5 codes when a dryer is not heating.

CodeWhat it meansMaytag says
AFAir isn't flowing freely through the dryer. It keeps running, but loads take longer to dry. Some models light Check Vent instead.You can usually clear it
L2The dryer is getting low voltage or none on part of its supply, so the heater may not come on. The drum keeps turning.You can usually clear it
F3 E1A fault with the temperature sensor on the exhaust.Needs a technician
F3 E3A fault with the temperature sensor on the air inlet.Needs a technician
F4 E1There may be a problem with the heater or the relays that switch it.Needs a technician

Codes differ between models. No code on the display? The checks below still apply.

What to check first

These are in rough order of how often they are the cause. Each can be checked without opening the dryer up.

  1. A half-tripped breaker (electric dryers). The drum turns and the light works, but there is no heat at all.
    An electric dryer runs on two breakers joined together. If one trips, the drum still turns. Switch the dryer's breaker fully off, then back on.
  2. A clogged lint screen. Clothes take longer and longer to dry, and the screen looks clean but water pools on it.
    Clean the lint screen. If water sits on it instead of running through, wash it with warm soapy water and let it dry.
  3. A blocked vent. The dryer and the clothes get hot but stay damp, or the dryer cuts out. Little or no air comes out of the vent outside.
    Go outside while the dryer runs. The vent flap should open and blow warm air. Clear any lint from the flap.
  4. A no-heat setting. It started after someone changed the cycle.
    Make sure the cycle is not Air Fluff or Air Dry, and that Eco or Energy Saver is off. Run a timed cycle on high heat to test.

What needs a technician

If the checks above change nothing, it is usually one of these. They mean opening the dryer up, which is not a job to do yourself.

Stop and call someone if

Don't remove panels, and don't reach inside with the power on. Smell gas, or see smoke or sparks? Stop, leave, and call 911.

More on Maytag

Other makers

Other dryer problems

The causes on this page were written with AI from general repair knowledge and have not yet been reviewed by a technician. Code meanings read from Maytag product help: error codes in dryers and written in our own words. Last checked 11 November 2026. SerialPlate gives guidance, not a guarantee.